buy generic karela canadian pharmacy without prescription

A new study suggests a new coronavirus test developed by scientists from the University of Washington and the Brotman Baty Institute for Precision Medicine produces faster and more sensitive results than conventional PCR tests to measure severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) viral RNA.

The RT-LAMP test kit known as “Harmony COVID-19” is a point-of-care test designed to be inexpensive and straightforward to use with the ability to examine up to four samples at once. The device is intended to better help healthcare workers in identifying SARS-CoV-2 in patients.

The researchers also hope to extend Harmony COVID-19 for rapid testing of other respiratory infections, including seasonal SARS-CoV-2, influenza, minomycin how long does it take to work and RSV.

The team writes:

“Tests such as Harmony will become a common practice for confirming the presence of viral infections that can be treated with antiviral therapies or that demand infection control, as well as helping to reduce inappropriate use of antibiotics. Further, test platforms developed for this pandemic could be more readily adapted to detect new diseases to increase readiness for future pandemics.”

The study “Harmony COVID-19: a ready-to-use kit, low-cost detector, and smartphone app for point-of-care SARS-CoV-2 RNA detection” is published on the preprint medRxiv* server.

How they did it

The Harmony COVID-19 test kit was assessed in the current study by having healthcare workers measure the RNA of contrived specimens from the nasal and saliva matrix. In addition, healthcare workers also measured RNA from stored clinical samples.

Fresh clinical samples could not be obtained in time for the study, which the authors acknowledge is a limitation of the study.

Healthcare workers learned how to use the test through some written instructions and a video detailing the procedure.

Harmony COVID-19 workflow, analytical performance, and interpretation. (A) User workflow. A nasal swab is collected and eluted in the rehydration buffer using either a unified sampler-dispenser (shown) or a tube-and-bulb method (Fig. 8). The swab eluate is then transferred into the reaction tube to rehydrate lyophilized, pre loaded RT-LAMP reagents. Users follow the instructions on the cell phone app to record the sample identity, insert the tube in the test slot, and close the device. Four samples can be analyzed in parallel. (Photo credits: (A)1-(A)4, Mark Stone at the University of Washington and (A)5, Christopher Snyder at North Seattle College). (B) Examples of on-device analysis. Lyophilized reagents were rehydrated with the eluate from swabs spiked with 0, 200, 2000, or 20,000 copies of SARS-CoV-2 RNA, run on the device, and analyzed in real-time. The samples with SARS-CoV-2 RNA at 2000, 200, and 20 copies/reaction (rxn) were reported as positive by software at 27 min, 30 min, and 41 min, respectively; after 60 min the NTC reaction was classified as negative. (C) Time-to-result. Individual detection time points (n = 3) are plotted. Variation in detection time increases as samples approach the detection limit. (D) Diagnostic algorithm. Harmony COVID-19 software calls samples as positive, negative, or indeterminate based on detection of the three regions in the nucleocapsid gene (Harmony NC1 overlapping with the CDC N1 region, Harmony NC2 (overlapping with CDC N3 region excluded from the current kit), and Harmony NC3 overlapping with the CDC N2 region) and the engineered IAC sequence.

Results suggest high accuracy and sensitivity in testing assay

Testing of Harmony COVID-19 produced an inexpensive and straightforward rapid test with features similar to conventional laboratory-based tests. Healthcare workers had a 95% accuracy while using the assay.

Results also showed the Harmony COVID-19 testing kit had high sensitivity.

Ready-to-use reagents in the testing kit helped with specificity and accuracy. The assay detected about 15 copies/reaction of synthetic SARS-CoV-2 RNA and real RNA samples collected at more than 20 copies/reaction with no false positives. The test was also able to give results for high viral load samples in 17 minutes.

The test also successfully detected samples with more than 20 viral particles in the human nasal matrix. In addition, the test had moderate sensitivity for saliva at similar concentrations.

Specifically, about 97% of contrived samples in the nasal matrix was detected, and 83% of samples were detected in saliva.

“Our current level of assay sensitivity would be sufficient to detect SARS-CoV-2 in most nasal specimens (~103 to ~109 copies/swab) or saliva (~104 to ~108 copies/mL) infected individuals during the first week after the onset,” explained the research team.

The researchers attributed the test’s high sensitivity and specificity to using a novel polymerase and probe design to specify between SARS-CoV-2 from IAC amplification.

Improvements to the assay

The researchers point out that the testing assay could be modified to increase the detection of SARS-CoV-2. They explain that conducting the test at a cooler and more optimal temperature for the reverse transcriptase enzyme followed by a higher temperature for DNA amplification could potentially increase the speed or sensitivity of SARS-CoV-2 detection.

Using an RNA internal amplification control that more accurately reflects the SARS-CoV-2 virus and that can be packaged in a viral envelope could also improve results. The current study had the Harmony COVID-19 assay use a DNA internal amplification control, which fails to grasp lysis and cDNA conversion processes.

“The advances in awareness and acceptance of testing for infections at scale, and the technology platforms developed will have an ongoing benefit for COVID-19 control, reducing harm from other endemic diseases, and fighting future pandemics,” concluded the research team.

*Important Notice

medRxiv publishes preliminary scientific reports that are not peer-reviewed and, therefore, should not be regarded as conclusive, guide clinical practice/health-related behavior, or treated as established information.

Journal reference:
  • Panpradist N, et al. Harmony COVID-19: a ready-to-use kit, low-cost detector, and smartphone app for point-of-care SARS-CoV-2 RNA detection. medRxiv, 2021. doi: https://doi.org/10.1101/2021.08.12.21261875, https://www.medrxiv.org/content/10.1101/2021.08.12.21261875v1

Posted in: Device / Technology News | Medical Research News | Disease/Infection News

Tags: Assay, Cell, Coronavirus, Coronavirus Disease COVID-19, Diagnostic, DNA, Enzyme, Gene, Healthcare, Infection Control, Influenza, Laboratory, Medicine, Pandemic, Polymerase, Reagents, Research, Respiratory, Reverse Transcriptase, RNA, SARS, SARS-CoV-2, Severe Acute Respiratory, Severe Acute Respiratory Syndrome, Syndrome, Virus

Comments (0)

Written by

Jocelyn Solis-Moreira

Jocelyn Solis-Moreira graduated with a Bachelor's in Integrative Neuroscience, where she then pursued graduate research looking at the long-term effects of adolescent binge drinking on the brain's neurochemistry in adulthood.

Source: Read Full Article