Sweat sensor could alert doctors, patients to looming COVID cytokine storm

Sweat sensor could alert doctors, patients to looming COVID cytokine storm (video)

Early in the COVID-19 pandemic, doctors recognized that patients who developed a “cytokine storm”—a surge of pro-inflammatory immune proteins—were often the sickest and at highest risk of dying. But a cytokine storm can also occur in other illnesses, such as influenza. Today, scientists report preliminary results on a sweat sensor that acts as an early warning system for an impending cytokine storm, which could help doctors more effectively treat patients.

The researchers will present their results today at the spring meeting of the American Chemical Society (ACS).

“Especially now in the context of COVID-19, if you could monitor pro-inflammatory cytokines and see them trending upwards, you could treat patients early, even before they develop symptoms,” says Shalini Prasad, Ph.D., the project’s principal investigator, who is presenting the work at the meeting.

Early detection is important because once a cytokine storm has been unleashed, the excessive inflammation can damage organs, causing severe illness and death. In contrast, if doctors could administer steroidal or other therapies as soon as cytokine levels begin to rise, hospitalizations and deaths could be reduced.


https://youtube.com/watch?v=790i7celD7s%3Fcolor%3Dwhite

Although blood tests can measure cytokines, they are difficult to perform at home, and they can’t continuously monitor the proteins’ levels. Cytokines are excreted in sweat at lower levels than in blood. To collect enough sweat for testing, scientists have asked patients to exercise, or they have applied a small electrical current to patients’ skin. However, these procedures can themselves alter cytokine levels, Prasad notes. “When it comes to cytokines, we found that you have to measure them in passive sweat. But the big challenge is that we don’t sweat much, especially in air-conditioned environments,” she says. Prasad, who is at the University of Texas at Dallas, estimates that most people produce only about 5 microliters, or one-tenth of a drop, of passive sweat in a 0.5-inch square of skin in 10 minutes.

So the researchers wanted to develop an extremely sensitive method to measure cytokine levels in tiny amounts of passive sweat. They drew on their previous work on a wearable sweat sensor to monitor markers of inflammatory bowel disease (IBD). The wristwatch-like device, which is being commercialized by EnLiSense LLC (a company co-founded by Prasad), measures the levels of two proteins that spike during IBD flare-ups. When the device is worn on the arm, passive sweat diffuses onto a disposable sensor strip that is attached to an electronic reader. The sensor strip, which contains two electrodes, is coated with antibodies that bind to the two proteins. Binding of the proteins to their antibodies changes the electrical current flowing through the e-reader. The reader then wirelessly transfers these data to a smartphone app that converts electrical measurements to protein concentrations. After a few minutes, the old sweat diffuses out, and newly excreted sweat enters the strip for analysis.

For their new cytokine sensor (called the SWEATSENSER Dx), the researchers made sensor strips with antibodies against seven pro-inflammatory proteins: interleukin-6 (IL-6), IL-8, tumor necrosis factor-α (TNF-α), TNF-related apoptosis-inducing ligand, IL-10, interferon-γ-induced protein-10 and C-reactive protein. They inserted the strips into their device and, in a small observational study, they tested them on six healthy people and five people with influenza. Two of the sick people showed elevated cytokine levels, and in all participants, cytokines in passive sweat correlated with levels of the same proteins in serum.

The SWEATSENSER Dx was even sensitive enough to measure cytokines in patients taking anti-inflammatory drugs, who excrete cytokines in the low-picogram-per-milliliter concentration range. The device tracked cytokine levels for up to 168 hours before the sensor strip needed to be replaced.

Source: Read Full Article